Independent guide, not a government programFree for homeownersFigures checked November 21, 2026
Oxford NorfolkHome Energy
Home / Winter performance

Do heat pumps work in an Oxford or Norfolk winter?

Yes, when it's a cold climate model sized for your house. Here are the local numbers an installer should size to, and what to expect on the coldest nights.

How cold it gets here

Ontario's Building Code sets a winter design temperature for each place: the temperature a heating system must handle. Only the coldest 2.5% of January hours are colder.1

PlaceJanuary design (2.5%)January 1%Heating degree-days
Woodstock-19°C-21°C3,910
Ingersoll-18°C-20°C3,920
Tillsonburg-17°C-19°C3,840
Simcoe-17°C-19°C3,700
Nanticoke (Port Dover)-15°C-17°C3,600

The Building Code doesn't list Norwich or Delhi. Use the nearest towns above. Heating degree-days measure how much heating a winter needs; higher means more.

What the rebate demands of the equipment

To earn the Ontario rebate, a cold climate heat pump must still deliver at least 70% of its rated heating output at -15°C, at an efficiency of 1.8 or better. That means 1.8 units of heat for each unit of electricity, at a temperature where baseboard heaters manage 1. It must also be variable speed and on Natural Resources Canada's eligible list.2

What a real test showed

Natural Resources Canada tested a cold climate heat pump in a research house in Ottawa, designed for -25°C, colder than any town on this site. Its efficiency ranged from an average of 1.5 at -21.1°C to 3.0 at +4.9°C. With a 10 kW electric backup heater, it kept the house comfortable at the coldest temperatures of the test, below -21°C, though indoor temperatures swung more than with a standard system, and the supply air cooled during defrost until the backup warmed it.3 The test was published in 2013 and covered one unit.

Backup heat, by fuel

Sizing is the whole game

The Ontario rebate requires the contractor to size the system with Natural Resources Canada's sizing tool, for the whole home including the basement.2 Ask to see that sizing form with your quote. An undersized system leans on backup heat; an oversized one costs more up front.

Common questions

Will a heat pump keep my house warm at -20°C?
A properly sized cold climate heat pump keeps working well below zero, with backup heat for the coldest hours. In a Natural Resources Canada test, a cold climate unit kept a house comfortable below -21°C with an electric backup heater in place.
Do I need backup heat?
Usually, yes, for the coldest hours and defrost cycles. Electric resistance backup is common. Wood and electric homes can keep their existing heat as backup under the Ontario rebate rules.
What happens during defrost?
Frost builds on the outdoor unit in cold, damp weather, so the system briefly reverses to melt it. The air from the vents cools during that time unless backup heat warms it.