Under Ontario's Home Renovation Savings Program, your contractor must submit an NRCan Air Source Heat Pump Sizing and Selection Tool form for each outdoor unit. The form picks one of four sizing options, A to D. Gas and propane homes may use any of them, while oil, wood and electrically heated homes may use only C and D. The system must also be able to heat the whole conditioned space, basement included.1
See what your home gets, in about a minute.
Check my rebateWhat the sizing form is and who files it
The form comes from Natural Resources Canada. The contractor fills it in with your home's details and submits it with the pre-installation application, one form per outdoor unit.1 You don't file it yourself, but you can ask to see it.
It matters because it is the record of how the installer chose the equipment. A quote that says "3 ton" and nothing else tells you the unit size. The form tells you why.
Options A to D in plain words
The program describes the options like this, and here is what each means for a house:1
| Option | Program wording | In plain words |
|---|---|---|
| A | Emphasis on cooling | In practice, sized mainly for cooling, so a backup system carries more of the heating. |
| B | Balanced heating and cooling | In practice, sized to balance heating and cooling, with backup for more of the cold weather. |
| C | Emphasis on heating | In practice, sized with the emphasis on heating. |
| D | Sized on design heating load | In practice, sized on the home's design heating load. |
A bigger heat pump costs more to buy, but it covers more of the winter. A smaller one costs less and leans harder on the backup.
The program also sets a floor on the equipment itself. A qualifying unit must keep at least 70% of its rated capacity at -15°C and deliver a COP of at least 1.8 at that temperature.1 Sizing then decides how much of your winter that capacity has to cover.
Which fuels may use which option
- Natural gas or propane: options A, B, C and D are all eligible.
- Oil, wood or electric heat: only C and D are eligible.
Those rules come straight from the program requirements.1 They mean an oil, wood or baseboard home has to buy a heat pump that carries most or all of the heating. A gas or propane home can keep its furnace and go smaller.
If you are weighing a hybrid, the hybrid heat article explains how the furnace fits in. Wood heat is covered in keeping the stove.
The whole home, basement included
The program requires that the system be able to heat the whole conditioned space, including the basement, and to run year-round for heating and cooling.1
That affects farmhouses most. A heat pump sized for the main floor alone, with the basement left to a woodstove or a few baseboard heaters, is unlikely to meet that requirement, so ask the contractor how the basement will be heated. Check that the sizing form counts every heated square foot in the house, including a finished basement.
The local numbers a sizing should respect
A sizing calculation starts with how cold the house has to stay warm in. The Ontario Building Code lists two numbers for each place: a January design temperature and the heating degree-days below 18°C. The Code says the outside winter design temperature is the January 2.5% value.2
| Place | January design temperature | Degree-days below 18°C |
|---|---|---|
| Woodstock | -19°C | 3,910 |
| Ingersoll | -18°C | 3,920 |
| Tillsonburg | -17°C | 3,840 |
| Simcoe | -17°C | 3,700 |
| Port Dover (Nanticoke) | -15°C | 3,600 |
The Code table doesn't list Norwich or Delhi. The nearest listed places have design temperatures of -17°C to -19°C.2
Think of the design temperature as the cold night the system is built for. A house in Woodstock is sized against -19°C, and a house in Port Dover against -15°C. The degree-days add up how much heating a whole season needs, which is why two houses with the same design temperature can still burn different amounts of fuel.
Your own house can differ from the table. Insulation, windows, air leakage and a drafty farmhouse addition all change the heat loss. The sizing form should rest on the home's real measurements, with these local temperatures as the starting point.
What to ask the installer
- Which sizing option (A, B, C or D) did you choose, and why that one?
- What design temperature did you use for my address?
- What heat loss did you calculate for my house, and how did you measure it?
- Does the form include the basement and any additions?
- What heats the house on the coldest nights, and who sets that up?
- Can I see the completed NRCan form before the pre-installation application goes in?
A good installer answers these without fuss. If the answers come back vague, take that as information. Our rebate checker shows which option group your home falls into before you start those conversations.
See what your home qualifies for
Seven questions, about a minute, with the rules for your fuel.
Common questions
What is the NRCan sizing form?
It is the NRCan Air Source Heat Pump Sizing and Selection Tool form, which your contractor submits for each outdoor unit as part of the Ontario rebate application.1
Which sizing option do I need for oil heat?
Only options C and D qualify for oil, wood and electrically heated homes. Both mean the heat pump carries most or all of the heating.1
Is a bigger heat pump always better?
Not always. A larger unit costs more and covers more of the winter, but the right size depends on the house's heat loss and on whether a backup furnace is staying. Ask to see the calculation.
What design temperature applies to Woodstock?
The Building Code lists -19°C as the January 2.5% design temperature for Woodstock, with 3,910 heating degree-days.2